  • JFC DC Heat Pipe Aircon

    JFC DC Heat Pipe Aircon

    Core Advantages

    ◆ Adopt double cold source design,high refrigeration reliability

    ◆ Fast installation and short equipment maintenance time

    ◆ The equipment can adaptto various environments and can operate normally at-35℃~48℃

    ◆ The use of full DC48V powersupply can achieve low carbon and energy savingeffect,with the EER of 5.2andthe EER of heat pipe mode>10

    ◆ Low noise design will not disturb residents'daily life

    ◆ Equpped with intelligent management system,multiple mains power monitorngmodes,and powermetering

    ◆ Dual compressor,dual fan and dual controller backup design can prevent shutdown caused by single compo-nentfailure

  • CNA Precision Air Conditioner for Computer Room

    CNA Precision Air Conditioner for Computer Room

    Core Advantages

    ◆ EER upto 3.6

    ◆ The indoorunit occupies a Min.area of 0.22m²

    ◆ Innovative design of "double DC axial flow fan"

    ◆ "Large air volume,small enthalpy difference"design,SHR ≥92%

    ◆ The indoor unit is designed with three return air sides sup- porting full frontal maintenance

    ◆ Power off memory,autostart,-15~48℃operation environ- ment

  • Inverter CSA Precision Air Conditioner for Computer Room

    Inverter CSA Precision Air Conditioner for Computer Room

    Core Advantages

    ◆ Full inverter design,provide more flexible and efficient temperature control scheme

    ◆ With Wet film humidification,power consumption is greatly reduced

    ◆ Power off memory,autostart,group control,flexible con- figuration

    ◆ *Optional lightning protection component,ensuring the stability of the equipment room

    ◆ *Optional low temperature components,which can achieve-35℃ reliable operation

  • FHF Heat Pipe Integrated Air Conditioner

    FHF Heat Pipe Integrated Air Conditioner

    Core Advantages

    ◆ Power saving reach up to 30~60%.

    ◆ Compressors are recommended for cooling in summer to ensure controllable temperature in the equipment room.

    ◆ Heat pipes are recommended for natural cooling in winter to minimize energy consumption

    ◆ In transition season,the intelligent mode should be adopted to switch the refrigeration type automatically

    ◆ 580mm wide,downward air supply,CFD simulation

    ◆ Outdoor ambient temperature ranging from-30℃to 48℃

    ◆ Autostart function,to achieve free manual patrol

    ◆ *Optional power metering function module

  • CMC Room-Based Precision Air Conditioner(Chilled water)

    CMC Room-Based Precision Air Conditioner(Chilled water)

    Core Advantages

    ◆ Key components are selected from well-known brands

    ◆ EC fan,stepless inverter adjustment,energy saving 30%

    ◆ High efficiency electrode humidification,fast humidifica- tion,less power consumption

    ◆ Full frontal maintenance,pull-out design

    ◆ 7 inch LCD touch screen,perfect man-machine interaction

    ◆ Power off memory,autostart,group control,flexible con- figuration

    ◆ *Optional power metering function module

  • CMF Room-Based Aircon(Refrigerant pump)

    CMF Room-Based Aircon(Refrigerant pump)

    Core Advantages

    ◆ Three operating modes,automatic switching,real-time adjustment

    ◆ Pump cabinet system series design,highintegration,more energy saving

    ◆ The pump cabinet is integrated on the outdoor side,with- out requiring addtional space for placement

    ◆ Integrated highly efficient energy-saving algorithm,group control support,rotation,cascade

    ◆ Modular design,full frontal maintenance,pull-out design

    ◆ Full frontal maintenance,pull-out design

    ◆ Applicability upgrade,can be applied to 95%of the area

    ◆ *Optional power metering function module

  • CRF Row-Based Aircon(Refrigerant pump)

    CRF Row-Based Aircon(Refrigerant pump)

    Core Advantages

    ◆ Key components are selected from well-known brand

    ◆ FullEC inverter design,automatic adjustment of cooling capacity and air volume output

    ◆ Wet film humidifier,saving 99%of humidification energy

    ◆ "Linear shape or U shape"evaporator,large area,small resistance

    ◆ High return air temperature design,energy efficiency significantly improved

    ◆ Three operating modes,automatic switching,real-time adjustment

    ◆ Pump cabinet system series design,high integration, more energy saving unit

    ◆ The pump cabinet is integrated on the outdoor side,with- out requiring additional space for placement

    ◆ Integrated efficient energy-saving algorithm,support group control,rotation,cascade

  • CDA Rack Aircon

    CDA Rack Aircon

    Core Advantages

    ◆ The height of the 5kW model is only 5U,saving the avail- able space in the cabinet

    ◆ Supports temperature sensing management at the top of the cabinet to prevent local hot spots

    ◆ Multiple drainage and anti-flooding design to prevent cabinet flooding

    ◆ Intelligent self-detection of refrigerant capacity and intel- ligent warning

    ◆ High efficiency inverter compressor,super precise PID control technology

    ◆ Electronic expansion valve enables smooth adjustment of throttle

    ◆ Opening EC centrifugal fan,adjust air volume output ratio in real time as required

    ◆ Extremely wide network adaption,which can meet±20% voltage range

  • HyperRow600Row Base Micro Modular Data Center

    HyperRow600Row Base Micro Modular Data Center

    Core Advantages

    ◆ The 2M standard cabinet has a larger 43U capacity

    ◆ Support one+drag(1-8)cabinet combination

    ◆ Without additional components,cabinets are directly cou- pled and assembled,forming a "double-aisle closure onthe hot and cold sides"system

    ◆ The cabinets can be installed on the concrete floor and is suitable for the computer room with an elevated floor

    ◆ Ultra wide voltage range:138~485V

    ◆ Ultra wide temperature range:-40~55℃

  • HyperBlock2000 Double Row Micro Modular Data Center

    HyperBlock2000 Double Row Micro Modular Data Center

    Core Advantages

    ◆ Integrated PUE value within the module as low as 1.25 (Beijing area)

    ◆ The 2M standard cabinet with a larger 43U capacity

    ◆ The self-made row-based air conditioner provides near-end refrigeration,reducing air static pressure loss by60%,and supports optional free cooling

    ◆ Self-made UPS,the overallefficiency is 96.8%

    ◆ From the module components to the whole,all have passed the 9-level seismic test and meet the A-level/Tier3+standard

    ◆ Haiwu provides customized design services